ESD Glossary of Terms

(as defined by Fowler Associates, the EIA & the ESD Association)


K
Q
U
X
Y


A

Air Conductivity - The ability of air to conduct (pass) an electric current under the influence of an electric field.

Air Ion - A molecular cluster of about 10 molecules (water, impurities, etc.) bound by polarization forces to a singly charged oxygen or nitrogen molecule.

Air Ionizer - A source of charged air molecules (ions).

Ankle Strap - See Ground Strap.

Antistat, Agent - A substance that is part of or topically applied to a material to render the material surface static dissipative or less susceptible to triboelectric charging.

Antistatic - Usually refers to the property of a material that inhibits triboelectric charging. Note: A material's antistatic characteristic is not necessarily correlatable with its resistivity or resistance.

Auxiliary Ground - A Separate supplemental grounding conductor for use other than general equipment grounding, that is bonded to the equipment grounding conductor.

 

 


Barrier Strip - A device or apparatus that consists of a metal strip and connectors or screws that allow termination and connection of wires or conductors from various components of an electrostatic discharge protected workstation. (See Bus Bar)

Bond or Bonding - The permanent joining of metallic parts to form an electrically conductive path that will assure electrical continuity and the capacity to safely conduct any current likely to be imposed.


Bus Bar - A metal strip or bar to which several conductors may be bonded.
 

 

C

(return to top)

Charge Decay - The decrease and/or neutralization of a net electrostatic charge.


Charge Induction - The displacement of charge in an isolated conductor when placed in an electric field (for example, from a charged body). Note: Momentary grounding of such a conductor would result in its gaining a net charge.

Charged Device Model - A specified circuit characterizing an electrostatic discharge which results when a device isolated from ground is first charged and then subsequently grounded.

Cold Healing - The spontaneous recovery, at room temperature, of an item from a parametric change caused by electrostatic discharge.

Cold Workstation - A work area that has items, assemblies, black boxes, or systems to which no power is applied.

Common Point Ground - (1) A grounded device where two or more conductors are bonded. (2) A system or method for connecting two or more grounding conductors to the same electrical potential.

Component - An Item such as a resistor, diode, transistor, integrated circuit and hybrid.


Component Failure - A condition in which a tested component does not meet one or more specified static or dynamic data sheet parameters.

Compressed Gas Ionizer - ionization devices used to simultaneously neutralize charged surfaces and remove surface particles with high pressure gas. This type of ionizer may be used to ionize the gas within production equipment.

Conductive Material - A material that has a surface resistivity less than 1 x 105 ohms/square or a volume resistivity less than 1 x 104 ohm-cm.

Conductivity - 1. The ratio of the current per unit area (current density) to the electric field in a material. Conductivity is expressed in units of siemens/meter. 2. In non-technical usage, the ability to conduct current.

Corona - The production of positive and negative ions by a very localized high electric field. The field is normally established by applying a high voltage to a conductor in the shape of a sharp point or wire.

 

D
(return to top)


Decay Rate - The decrease of charge or voltage per unit time.

Decay Time - The time required for an electrostatic potential to be reduced to a given percentage (usually 10%) of its initial value. (See Static Decay Test.)

Dielectric - An insulating material that can sustain an electric field with little current flow.

Dielectric Breakdown Voltage - The electric potential across an insulating material that causes a sudden increase in current through the material of the insulator.

Dielectric Strength- The maximum electric field that a dielectric can sustain.

Discharge Time - The time necessary for a voltage (due to an electrostatic charge) to decay from an initial value to some arbitrarily chosen final value.


Dynamic Parameters - Those measured with the component in a functioning condition, and may include, but are not limited to: full functionality, output rise and fall times under a specified load condition, and dynamic current draw.

E
(return to top)


Electric Charge - An absence or excess of electrons.

Electrical Ionizer - A device that creates ions in gases by use of high voltage electrodes.

Electrical Overstress (EOS) - The exposure of an item to a current or voltage beyond its maximum ratings. This exposure may or may not result in a catastrophic failure.

Electrification Period - The average of five electrification times, plus five (5) seconds.


Electrification Time - The time for the resistance measuring instrument to stabilize at the value of the upper resistance range verification fixture.

Electrostatic Charge - Electric Charge at rest.

Electrostatic Damage-
Change to an item caused by an electrostatic discharge
that makes it fail to meet one or more specified parameters.

Electrostatic Discharge (ESD) - The rapid, spontaneous transfer of electrostatic charge induced by a high electrostatic field . Note: Usually, the charge flows through a spark between two bodies at different electrostatic potentials as they approach one another. Details of such processes, such as the rate of the charge transfer, are described in specific electrostatic discharge models.

Electrostatic Discharge Control - see Static Control

Electrostatic Discharge Ground - The point, electrodes, bus bar, metal strips, or other system of conductors that form a path from a statically charged person or object to ground.


Electrostatic Discharge Protected Area - A designated environment provided with materials and equipment to limit electrostatic potentials.

Electrostatic Discharge Protective - A property of materials capable of one or more of the following: reducing the generation of static electricity, dissipating an electrostatic charge, or providing shielding from electrostatic discharge or electrostatic fields.


Electrostatic Discharge Protective Workstation - An area that is constructed and equipped with the necessary protective materials and equipment to limit damage to electrostatic discharge susceptible items handled therein.

Electrostatic Discharge Protective Worksurface - A worksurface that dissipates electrostatic charge from materials placed on the surface or from the surface itself.

Electrostatic Discharge Sensitivity (ESDS) - The electrostatic discharge level that causes component failure.


Electrostatic Discharge Shield - A barrier or enclosure that limits the passage of current and attenuates an electromagnetic field resulting from an electrostatic discharge.

Electrostatic Discharge Spark Testing - Testing performed with operating equipment or parts to determine their susceptibility to the transient electromagnetic fields produced by an air discharge event.

Electrostatic Discharge Susceptibility (sensitivity) (ESDS) - The propensity to be damaged by electrostatic discharge.

Electrostatic Discharge Susceptibility Classification - The classification of items according to electrostatic discharge susceptibility voltage ranges. Note: There are various classification methods.

Electrostatic Discharge Susceptibility Symbol - The graphics placed on hardware, assemblies, and documentation for identification of electrostatic discharge susceptible items.

Electrostatic Discharge Susceptible Item - Electrical or electronic piece part, device, component, assembly, or equipment item that has some level of electrostatic discharge susceptibility.

Electrostatic Discharge Withstand Voltage - The maximum electrostatic discharge level that does not cause component failure.

Electrostatic Field -An attractive or repulsive force in space due to the presence of electric charge.

Electrostatic Potential - The voltage difference between a point and an agreed-upon reference.

Electrostatic Shield - A barrier or enclosure that limits the penetration of an electrostatic field.

Electrostatics - The study of electrostatic charge and its effects.

Emitter - A conducting sharp object, usually a needle or wire, which will cause a corona discharge when kept at a high potential.

EOS - See Electrical Overstress.

Equipment Ground- 1. The ground point at which the equipment grounding conductor is bonded to any piece of equipment, at the equipment end of the conductor. 2. The 3rd wire (green) terminal of a receptacle. 3. The entire low impedance path from a piece of electrical equipment to a hard ground electrode.

ESD - See electrostatic discharge.

ESD Sensitivity - See electrostatic discharge susceptibility.

ESDS - See electrostatic discharge susceptibility.

F
(return to top)


Faraday Cage - A conductive enclosure that attenuates a stationary electrostatic field.

Field Induced Charging - A charging method using electrostatic induction.

 

G
(return to top)

 
Ground - 1.A conducting connection, whether intentional or accidental between an electrical circuit or equipment and the earth, or to some conducting body that serves in place of earth. 2. The position or portion of an electrical circuit at zero potential with respect to the earth. 3. A conducting body, such as the earth or the hull of a steel ship, used as a return path for electric currents and as an arbitrary zero reference point.

Ground-Fault Circuit Interrupter - A device intended for the protection of personnel that functions to de- energize a circuit or portion thereof within an established period of time. It is activated when a current difference between the neutral and hot conductors exceeds some predetermined value that is less than that required to operate the over current protective device of the supply circuit. The current difference is usually caused by a current to ground.

Ground Strap - 1.A conductor intended to provide an electrical path to ground. 2. An item used by personnel with a specified resistance, intended to provide a path to ground.

Groundable Point - A designated connection, location or assembly used on an electrostatic discharge protective material or device that is intended to accommodate electrical connection from the device to an appropriate electrical ground.

Grounded Conductor - A system or circuit conductor that is intentionally grounded.


Grounded - Connected to earth or some other conducting body that serves in place of the earth.


Grounding Conductor - A conductor used to connect equipment or the ground circuit of a wiring system to a ground electrode or electrodes.

Grounding Resistance - The total resistance from any given point in an electrically conductive path to the grounding electrode.
 

H
(return to top)


Hard Ground - A connection to ground through a wire or other conductor that has very little or nearly no resistance (impedance) to ground.

Horizontal Laminar Flow - Non-turbulent air flow in a horizontal direction.


Hot Workstation - A work area that has items, assemblies, black boxes, or systems, which have power applied for testing or repair.

Human Body Model - An electrostatic discharge circuit that meets the set model values by conforming to the waveform criteria specified in ANSI/EOS/ESD-S5.1-1993, characterizing the electrostatic discharge from a human being.


Human Body Model Electrostatic Discharge - An electrostatic discharge event meeting the waveform criteria specified in ANSI/EOS/ESD-S5.1-1993, approximating the discharge from the fingertip of a typical human being.

Human Body Model Electrostatic Discharge Tester - Equipment that applies Human Body Model electrostatic discharges to a component.
 

I
(return to top)


Impedance - n. Symbol Z A measure of the total opposition to current flow in an alternating current circuit, made up of two components, ohmic resistance and reactance, and usually represented in complex notation as Z = R + iX, where R is the ohmic resistance and X is the reactance. Impedance is measured in ohms.

Inductive Charging - The transfer of an electric charge to an object when it is momentarily contacted to ground in the presence of an electric field.

Input Protection - Structures, devices or networks connected at the input terminals of an item to prevent electrostatic discharge damage.

Insulated Conductor - A conductor encased within material of composition and thickness that is recognized as electrical insulation.

Insulative Material - A material having a surface resistivity of at least 1 x 1012 ohms/square or 1 x 1011 ohm- cm volume resistivity.

Ionization - The process by which a neutral atom or molecule acquires a positive or negative charge.

Ionizer - A device which is designed to generate positive and/or negative air ions.


Isolated Conductor - A non-grounded conductor.

Isolated Ground Receptacle - A grounding type receptacle in which the equipment grounding conductor contact and terminal are electrically isolated from the receptacle mounting means.

 

J
(return to top)


Junction Damage - Electrical Overstress damage to a semiconductor junction.

Laminar Flow Hood Ionization - These devices or systems provide local area ionization coverage in vertical or horizontal laminar flow hoods or benches.

L
(return to top)


Latent Failure - A malfunction that occurs following a period of normal operation. Note: The failure may be attributable to an earlier electrostatic discharge event. The concept of latent failure is controversial and not totally accepted by all in the technical community.

 

M
(return to top)


Machine Model - An electrostatic discharge simulation test based on a discharge network consisting of a charged 200 picofarad capacitor and (nominally) zero ohms of series resistance. Actual series resistance and inductance are specified in terms of the current waveform through a shorting wire. The simulation test approximates the electrostatic discharge from a machine.

Machine Model Electrostatic Discharge - An event meeting the criteria specified in ESD-S5.2-1994.

Main Bonding Jumper - The connection between the grounded circuit conductor and the equipment grounding conductor at the service.

Monitor, Charge(d) Plate - An instrument used to measure the charge neutralization properties of ionization equipment.
 

N
(return to top)


Neutralize - To eliminate an electrostatic field by recombining positive and negative charges, either by conducting the charge to ground or by introducing an equal opposite charge.


Nuclear Ionizer - A device that creates ions usually by alpha emissions which strip electrons from gas molecules to form equal numbers of positive and negative ions in gases.

 

O
(return to top)


Offset Voltage - The observed voltage on the isolated conductive plate of a charged plate monitor that has been placed in an ionized environment.

Outlet - 1. A receptacle that is connected to a power supply and equipped with a socket for a plug. 2. A point on a wiring system at which current is taken to supply utilization equipment.

Output Protection - Structures, devices or networks connected at the output terminals of an item to prevent electrostatic discharge damage.


Oxide Punch-through - Dielectric breakdown of an oxide layer, as in a semiconductor device.

 

P
(return to top)


Passive Ionizer - A device, usually a sharp grounded needle point, that discharges surfaces in the immediate vicinity by creating a conductive path of air ions.

Peak Offset Voltage - For pulsed ionizers, the maximum value of the offset voltage for each polarity, as the ionizer cycles between positive and negative ion outputs.

Personnel Grounding Device - An electrostatic discharge protective device designed to ground any electrostatic charge accumulated on a person. NOTE: The resistance to ground of a personnel grounding device must be high enough to avoid causing an electrical shock hazard.

Planar Material - An item with a surface sufficiently large and flat to conform to the surface resistance measuring electrode described in EOS/ESD-S11.11-1993.

 

R
(return to top)


Receptacle - A contact device installed at the outlet for the connection of an attachment plug.

Ringing- Distortion in the form of a damped oscillatory waveform superimposed on the main waveform.

Room Ionization - ionization systems which provide large area coverage with air ions.

 

S
(return to top)

Service Equipment - The necessary equipment, usually consisting of a circuit breaker or switch and fuses, and their accessories, located near the point of entrance of supply conductors to a building or other structure, or an otherwise defined area, and intended to constitute the main control and means of cutoff of the supply.

Shunting Bar - A device that shorts together the terminals of an electrostatic discharge susceptible item forming an equipotential surface.

Spark - An electrical discharge of very short duration, normally between two conductors separated by a gas (such as air).

Static Control (or, Electrostatic Discharge Control) - 1. adj. - electrostatic discharge protective. 2. n. - Generic term for measures taken to diminish the effects of electrostatic discharge.

Static Decay Test - A procedure in which an item is first charged to a specified voltage, then allowed to dissipate to a specified voltage while measuring the duration of the discharge.

Static Dissipative - A property of a material having a surface resistivity of at least 1 x 105 ohms/square or 1 x 104 ohm-cm volume resistivity but less than 1 x 1012 ohms/square surface resistivity or 1 x 1011 ohm-cm volume resistivity.

Static Electricity - See electrostatic charge.

Static Parameters - Those measured with the component in a non-functioning condition, and may include, but are not limited to: input leakage current, input breakdown voltage, output high and low voltages, output drive current, and supply current.


Step Stress Test Hardening - A process whereby a component subjected to increasing electrostatic discharge voltage stress is able to withstand higher stress levels than a similar component stressed at a single lower voltage level. Note: As an example, a component may fail at one thousand volts if subjected to a single stress, but fail at three thousand volts if stressed at progressively higher voltages, starting at a low level, for example 250 volts.

Step Stress Testing - A test consisting of increasing stress levels applied sequentially to a sample for periods of equal duration.

Surface Resistance - The ratio of DC voltage to the current flowing between two electrodes of specified configuration that contact the same side of a material. This measurement is expressed in ohms.

Surface Resistivity (rs) - For electric current flowing across a surface, the ratio of DC voltage drop per unit length to the surface current per unit width. In effect, the surface resistivity is the resistance between two opposite sides of a square and is independent of the size of the square or its dimensional units. Surface resistivity is expressed in ohms/square. When using a concentric ring fixture, resistivity is calculated by using the following expression, where D1 = outside diameter of inner electrode, D2 = Inside diameter of outer electrode, and R = measured resistance in ohms:



T
(return to top)


Topical Antistat - An antistat that is applied to the surface of a material for the purpose of making the surface static dissipative or to reduce triboelectric charging.

Triboelectric Charging - The generation of electrostatic charges when two materials make contact or are rubbed together, then separated. (See also Triboelectric series.)

Triboelectric Series - A list of materials arranged so that one can become positively charged when separated from one farther down the list, or negatively charged when separated from one farther up the list. Note: The series' main utility is to indicate likely resultant charge polarities after triboelectric generation. However, this series is derived from specially prepared and cleaned materials tested in very controlled conditions. In everyday circumstances, materials reasonably close to one another in the series can produce charge polarities opposite to that expected. This series is only a guide.

 

V
(return to top)


Vertical Laminar Flow - Non-turbulent air flow in a vertical direction.


Voltage Suppression - Reduction of the voltage (V) of a charged object by increasing its capacitance (C) rather than by decreasing its charge (Q), in accordance with the formula V = Q/C. Note: Voltage suppression typically occurs when a charged object is brought closer to ground.

Volume Resistivity rv) - The ratio of the DC voltage per unit thickness to the amount of current per unit area passing through a material. Volume resistivity is given in ohm-centimeters.

W
(return to top)


Worksurface Groundable Point - A point on the worksurface that is intended to accommodate an electrical connection from the worksurface to an appropriate electrical ground.

Worksurface Ionization - ionization devices or systems used to control static charges at a work station. Note: This type includes benchtop ionizers, overhead worksurface ionizers, and laminar flow hood ionizers.

Z
(return to top)

 

Zap - (colloquial term) See electrostatic discharge.